Swiss federal authorities

Doel and Tihange

In the summer of 2012, a number of findings were registered in the base material of the forged reactor pressure vessel in the Belgian nuclear power stations Doel-3 and Tihange-2.

The Belgian supervisory authority Federaal Agentschap voor Nucleaire Controle (FANC) conducted a detailed investigation and came to the conclusion in spring 2013 that continued operation of the two facilities is possible under certain conditions.

In March 2014 operator electrabel decided to temporarily shut down the two plants after a material test provided unexpected results.

Top Article

  • News

    ENSI reviews Axpo’s project plan for the safety case of the Beznau 1 reactor pressure vessel

    Axpo submitted today a project plan (road map) to ENSI, the Swiss Federal Nuclear Safety Inspectorate, outlining procedures for the characterisation and evaluation of the indications in the base material of the Beznau 1 reactor pressure vessel. ENSI will review this plan in collaboration with a group of international experts.

News

  • News

    ENSI reviews Axpo’s project plan for the safety case of the Beznau 1 reactor pressure vessel

    Axpo submitted today a project plan (road map) to ENSI, the Swiss Federal Nuclear Safety Inspectorate, outlining procedures for the characterisation and evaluation of the indications in the base material of the Beznau 1 reactor pressure vessel. ENSI will review this plan in collaboration with a group of international experts.

  • News

    “Only an ultrasonic examination is capable of providing authoritative information regarding the current condition of the reactor pressure vessel.”

    The Swiss Federal Nuclear Safety Inspectorate (ENSI) requires the Beznau nuclear power plant to provide proof that the reactor pressure vessel is safe. In an interview, Georg Schwarz, the Director of the Division for Nuclear Power Plants and Deputy Director of ENSI, explains the importance of carrying out ultrasonic inspections.

  • News

    Beznau 2 can continue operating until the start of the annual overhaul in mid-August

    Block 2 of the Beznau nuclear power plant does not have to be shut down early. The operator Axpo was able to plausibly demonstrate to the Swiss Federal Nuclear Safety Inspectorate ENSI that even if one were to assume that the reactor pressure vessel of Beznau 2 had similar material defects to those in Beznau…

  • News

    More investigations are needed on the reactor pressure vessel of Beznau 1

    While carrying out ultrasonic measurements of the reactor pressure vessel of the Beznau 1 nuclear power plant the operator detected flaw indications that require evaluation. It submitted a corresponding report to the Swiss Federal Nuclear Safety Inspectorate ENSI yesterday. Beznau 1 is presently inactive because of the main annual overhaul. ENSI is now awaiting an…

  • News

    ENSI follows WENRA recommendation on review of reactor pressure vessels

    The Swiss nuclear power plants (NPP) Beznau and Gösgen are required to perform standardized safety reviews of the base materials in their reactor pressure vessels to check for possible manufacturing flaws. Through this requirement, the Swiss Federal Nuclear Safety Inspectorate ENSI is implementing a recommendation issued by the Western European Nuclear Regulators Association (WENRA).